    "CVE_data_meta": {
        "ASSIGNER": "zdi-disclosures@trendmicro.com",
        "ID": "CVE-2021-31505",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "Q Plus",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "1.9.0.3_278"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Arlo"
                }
            ]
        }
    },
    "credit": "Team FLASHBACK: Pedro Ribeiro (@pedrib1337 | pedrib@gmail.com) + Radek Domanski (@RabbitPro)",
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "This vulnerability allows attackers with physical access to escalate privileges on affected installations of Arlo Q Plus 1.9.0.3_278. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SSH service. The device can be booted into a special operation mode where hard-coded credentials are accepted for SSH authentication. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of root. Was ZDI-CAN-12890."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-798: Use of Hard-coded Credentials"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-683/",
                "refsource": "MISC",
                "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-683/"
            },
            {
                "url": "https://kb.arlo.com/000062592/Security-Advisory-for-Arlo-Q-Plus-SSH-Use-of-Hard-coded-Credentials-Allowing-Privilege-Escalation",
                "refsource": "MISC",
                "name": "https://kb.arlo.com/000062592/Security-Advisory-for-Arlo-Q-Plus-SSH-Use-of-Hard-coded-Credentials-Allowing-Privilege-Escalation"
            }
        ]
    },
    "impact": {
        "cvss": {
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
        }
    }
}