    "data_type": "CVE",
    "data_format": "MITRE",
    "data_version": "4.0",
    "CVE_data_meta": {
        "ID": "CVE-2021-27458",
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "n/a",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "JTEKT Corporation TOYOPUC products",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "TOYOPUC-PC10 Series: PC10G-CPU TCC-6353: All versions, PC10GE TCC-6464: All versions, PC10P TCC-6372: All versions, PC10P-DP TCC-6726: All versions, PC10P-DP-IO TCC-6752: All versions, PC10B-P TCC-6373: All versions, PC10B TCC-1021: All versions, PC10B-E/C TCU-6521: All versions, PC10E TCC-4737: All versions"
                                        },
                                        {
                                            "version_value": "TOYOPUC-Plus Series: Plus CPU TCC-6740: All versions, Plus EX TCU-6741: All versions, Plus EX2 TCU-6858: All versions, Plus EFR TCU-6743: All versions, Plus EFR2 TCU-6859: All versions, Plus 2P-EFR TCU-6929: All versions, Plus BUS-EX TCU-6900: All versions"
                                        },
                                        {
                                            "version_value": "TOYOPUC-PC3J/PC2J Series: FL/ET-T-V2H THU-6289: All versions, 2PORT-EFR THU-6404: All versions"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "IMPROPER RESOURCE SHUTDOWN OR RELEASE CWE-404"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "refsource": "MISC",
                "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-03",
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-03"
            }
        ]
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "If Ethernet communication of the JTEKT Corporation TOYOPUC product series\u2019 (TOYOPUC-PC10 Series: PC10G-CPU TCC-6353: All versions, PC10GE TCC-6464: All versions, PC10P TCC-6372: All versions, PC10P-DP TCC-6726: All versions, PC10P-DP-IO TCC-6752: All versions, PC10B-P TCC-6373: All versions, PC10B TCC-1021: All versions, PC10B-E/C TCU-6521: All versions, PC10E TCC-4737: All versions; TOYOPUC-Plus Series: Plus CPU TCC-6740: All versions, Plus EX TCU-6741: All versions, Plus EX2 TCU-6858: All versions, Plus EFR TCU-6743: All versions, Plus EFR2 TCU-6859: All versions, Plus 2P-EFR TCU-6929: All versions, Plus BUS-EX TCU-6900: All versions; TOYOPUC-PC3J/PC2J Series: FL/ET-T-V2H THU-6289: All versions, 2PORT-EFR THU-6404: All versions) are left in an open state by an attacker, Ethernet communications cannot be established with other devices, depending on the settings of the link parameters."
            }
        ]
    }
}