    "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2015-8214",
        "STATE": "PUBLIC"
    },
    "data_format": "MITRE",
    "data_version": "4.0",
    "data_type": "CVE",
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "n/a",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "n/a"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "n/a"
                }
            ]
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "n/a"
                    }
                ]
            }
        ]
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs."
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "78345",
                "refsource": "BID",
                "url": "http://www.securityfocus.com/bid/78345"
            },
            {
                "name": "1034279",
                "refsource": "SECTRACK",
                "url": "http://www.securitytracker.com/id/1034279"
            },
            {
                "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf",
                "refsource": "CONFIRM",
                "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf"
            },
            {
                "refsource": "CONFIRM",
                "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf",
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf"
            }
        ]
    }
}