    "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2014-8421",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "n/a",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "n/a"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "n/a"
                }
            ]
        }
    },
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "Unify (former Siemens) OpenStage SIP and OpenScape Desk Phone IP V3 devices before R3.32.0 allow remote attackers to gain super-user privileges by leveraging SSH access and incorrect ownership of (1) ConfigureCoreFile.sh, (2) Traceroute.sh, (3) apps.sh, (4) conversion_java2native.sh, (5) coreCompression.sh, (6) deletePasswd.sh, (7) findHealthSvcFDs.sh, (8) fw_printenv.sh, (9) fw_setenv.sh, (10) hw_wd_kicker.sh, (11) new_rootfs.sh, (12) opera_killSnmpd.sh, (13) opera_startSnmpd.sh, (14) rebootOperaSoftware.sh, (15) removeLogFiles.sh, (16) runOperaServices.sh, (17) setPasswd.sh, (18) startAccTestSvcs.sh, (19) usbNotification.sh, or (20) appWeb in /Opera_Deploy."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "n/a"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf",
                "refsource": "CONFIRM",
                "url": "https://networks.unify.com/security/advisories/OBSO-1501-02.pdf"
            },
            {
                "name": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt",
                "refsource": "MISC",
                "url": "https://www.modzero.ch/advisories/MZ-14-02-Siemens-Unify-OpenStage.txt"
            }
        ]
    }
}